Air Cooled Module Unit Chiller

Item No.: 92
Air cooled modular cold and hot water unit is a central air conditioning unit with air as cold and hot source and water as cold and hot medium. As an integrated equipment with both cold and hot functions, air-cooled modular cold and hot water units are cl
Description Technical data Related Products

■Applicable area: over 300m2.
■Applicable places:
Hotels, shopping malls, office buildings, exhibition halls, airports, stadiums and other public facilities.
■Product features:
High efficiency, energy saving, low noise, reasonable structure, simple operation, safe operation, convenient installation and maintenance.
Unique system design enables efficient operation in a wide temperature and pressure range.
Ordinary units can achieve the highest refrigeration environment temperature of 48℃, low-temperature units can achieve the lowest heating environment temperature of -20℃, high-temperature hot water units can achieve the highest hot water outlet temperature of 60℃.
■Naming rules:

Parameter table of common air cooled chiller
 
Product model Normal temperature LSQWRF35MT LSQWRF68MG LSQWRF130MG-S LSQWRF150MG-2VS
35℃ (ambient temperature) 7℃ (outlet temperature) Rated cooling capacity KW 32 65 130 140
Rated input power KW 10.5 21 42 46
7℃ (ambient temperature) 45℃ (outlet temperature) Rated heating capacity KW 35 68 136 150
Rated input power KW 11 21 43 48
Applicable power supply (V/PH/HZ) 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ
Refrigerant R22 R22 R22 R410A
Water side heat exchanger Rated cooling water flow m³/h 5.5 11.2 22.4 24.1
Rated heating water flow m³/h 6 11.7 23.4 25.8
Water resistance kPa 35 42 45 45
Pipe diameter of unit inlet and outlet pipe connections DN 40 50 65 65
Unit dimensions L mm 1500 2056 2450 2270
W mm 760 1106 1136 1286
H mm 1140 2045 2118 2130
Net weight kg 350 800 1300 1300
 
Note:
1.Nominal refrigeration condition: outdoor environment is 35℃, outlet water temperature is 7℃;
2. Nominal heating condition: outdoor dry/wet bulb temperature is 7℃/6℃, outlet water temperature is 45℃;
3. In actual use of intercooled heat, the loss of system pipelines, water pumps, valves, dirt, etc. after the unit is installed shall be considered to be about 6%.
4. The above models are single module parameters and can be used in combination of multiple modules, with a maximum of 16 modules.
5. Specifications are subject to change due to product improvement without prior notice.
 
R410A Series Air Cold Chiller Parameters with Low Loop Temperature and High Water Temperature

 
Product model Low temperature LSQWRF35MGALH LSQWRF45MGALH LSQWRF68MGALH LSQWRF85MGALH LSQWRF140MGALH LSQWRF150MGALH-2VZ LSQWRF150MGALH-2VS
35℃ (ambient temperature) 7℃ (outlet temperature) Rated cooling capacity KW 32 42 65 85 130 130 130
Rated input power45 KW 10.5 13.5 21.5 27 43 45 45
7℃ (ambient temperature) 45℃ (outlet temperature) Rated heating capacity KW 35 45 68 90 140 150 150
Rated input power KW 11 14 22 28 45.5 48 48
(-12)℃ (ambient temperature) 41℃ (outlet temperature) Heating capacity KW 24 29 48 58 96 100 100
Input power KW 9.5 12 19 24 38 41 41
(-12)℃ (ambient temperature) 50℃ (outlet temperature) Heating capacity KW 25 32 55 64 110 110 /
Input power KW 12 15 25 30 50 55 /
Applicable power supply (V/PH/HZ) 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ 3N/380V/50HZ
Refrigerant R410A R410A R410A R410A R410A R410A R410A
Water side heat exchanger Rated cooling water flow m³/h 5.5 7.2 11.2 14.6 22.4 22.4 22.4
Rated heating water flow m³/h 6 7.7 11.7 15.5 24.1 25.8 25.8
Water resistance kPa 35 35 40 45 45 45 45
Pipe diameter of unit inlet and outlet pipe connections DN 40 40 50 50 65 65 65
Unit dimensions L mm 1500 1720 2056 2160 2450 2270 2270
W mm 760 850 1106 1110 1136 1286 1286
H mm 1140 1140 2045 2000 2118 2130 2130
Net weight kg 350 420 800 1000 1300 1300 1300
 
Note:
1.Nominal refrigeration condition: outdoor environment is 35℃, outlet water temperature is 7℃;
2.Nominal heating condition 1: outdoor ambient temperature is 7℃, outlet temperature is 45℃;
3.Nominal heating condition 2: outdoor ambient temperature is -12℃, outlet temperature is 41℃;
4.Nominal heating condition 3: outdoor ambient temperature is -12℃, outlet temperature is 50℃;
5.This product implements the national standard: G B/T25127.1(2)-2010 heat pump (cold water) units for industrial or commercial use and similar uses
6.In actual use of intercooled heat, the loss of system pipelines, water pumps, valves, dirt, etc. after the unit is installed shall be considered to be about 6%.
7.The above models are single module parameters and can be used in combination of multiple modules, with a maximum of 16 modules.
8.Specifications are subject to change due to product improvement without prior notice.